View All Images
|
|
TSP High Volume Air Samplers
The high volume air sampler is U.S. EPAs Federal Reference Method for sampling total suspended particulates (TSP) in ambient air.
|
|
|
|
|
|
|
|
TSP High Volume Air Samplers Overview All TSP hi-vols feature accurate collection of total suspended particulates according to U.S. EPA specifications. Hi-vols have been used extensively in Federal, state and industrial monitoring networks for the measurement of ambient air quality standards for TSP and are used widely for occupational health monitoring and particulate research studies.
PRINCIPLE OF OPERATION
The high volume air sampler collects suspended particulates on large 8 x 10-inch (20.3 x 25.4cm) filter media. The name high volume is appropriate because the sampling flow rate has a high level of 20 to 60 standard cubic feet per minute (SCFM), or 0.57 to 1.71 standard cubic meters per minute (SCMM). Because of the high flow rate, large quantities of particles ranging from 0.1 to 1 gram are collected over a typical 24-hour sampling period. This facilitates gravimetric and chemical analysis and is the advantage hi vol samplers have over other air sampling methods.
FLOW CONTROL SYSTEMS
Two types of flow control systems are available. One is mass flow control (MFC), while the other is volumetric flow control (VFC).
- The flow rate in a MFC system is actively sensed and controlled at some pre-determined set point. Air is pulled through the filter into the intake of a blower and subsequently exits the sampler through an exit orifice, which facilitates measurement of the flow with a manometer or pressure recorder. The flow rate is controlled by an electronic mass-flow controller, which uses a flow sensor installed below the filter holder to monitor the mass flow rate and to control the speed of the motor accordingly. The controlled flow rate can be changed by an adjustment knob on the flow controller.
- A VFC system maintains a constant volumetric flow rate (given a fixed temperature) through the inlet, rather than a constant mass flow rate as in the MFC system. A choked-flow venturi is operated such that the air attains sonic velocity in the throat of the device. In this "choked" mode, the flow rate is unaffected by downstream conditions such as motor speed or exit pressure, and is a predictable function of upstream conditions, such as stagnation pressure ratio and temperature. Thus, the volumetric flow is controlled without any moving parts or electronic components. With this type of flow control system, no means is provided for adjusting the controlled flow rate.
LINK TO RELATED PRODUCTS
TSP High Volume Air Samplers Specifications
| Flow Rate |
39 to 60 cfm (1.1 to 1.7 cmm) for MFC;typically 42 to 45 cfm (1.2 to 1.3 cmm) for VFC |
| Mass Flow Control Accuracy |
±2.5% deviation over 24-hr period |
| Volumetric Flow Control Accuracy |
±1% deviation over 24-hr period |
| Flow Indicator(when supplied) |
Flow/pressure recorder with circular charts, 4" (10 cm) dia.; range 10 to 65 cfm (0 to 10" water |
TSP High Volume Air Samplers Design TSP High Volume Air Samplers Features
- Meets U.S. EPA 40 CFR Part 50, Appendix B - Reference Method for the Determination of Suspended Particulate Matter in the Atmosphere (High-Volume Method)
- Rugged anodized aluminum shelter
- 8 x 10-inch stainless steel filter holder
- Choice of mass flow control or volumetric flow control
- High speed motor designed for 24-hour continuous sampling
- Variety of timing devices available
- Optional brushless blower motor
|
Particle Instrumentation
Dependable Aerosol Particle Measurement
Regulatory personnel at the federal, state, and local level, as well as cleanroom managers and OSHA/NIOSH personnel rely on New Star Environmental for dependable particle measurement equipment. Our equipment meets all international standards for GIS and ISO standards for cleanrooms, and can be retrofitted to convert existing PM10 inlets to PM2.5 inlets. Plus, every piece of equipment is backed by 60 years of industry experience. So, when you need quality products and expert guidance, you need New Star.